Home > PRODUCTS > Manufacturers > Microwave Filter Company >

CATV Bandstop Filters for DOCSIS 3.1 Testing
CATV Bandstop Filters for DOCSIS 3.1 Testing
 
These bandstop filters are used for CATV equipment proofing/testing as it relates to DOCSIS 3.1.

Feature:
• Covers the entire 1218 MHz operating band.

Model 18926-Fo


18926-Fo Diagram
Specifications:
Stopband Center Frequency (Fo) Range63 - 111 MHz
StopbandFo ± 0.5 MHz
Stopband Attenuation55 dB Min
Passbands5 MHz to Fo - 5 MHz and
Fo + 5 MHz to 1218 MHz
Passband Insertion Loss3 dB Max.; 2 dB Typ
Passband VSWR1.5:1 Typ
Impedance75 ohms
ConnectorsF-female
Size19.00" x 3.46" (2 RU) x 4.63" Approx.

Model 18927-Fo


Specifications:
Stopband Center Frequency (Fo) Range549 - 1215 MHz
StopbandFo ± 0.5 MHz
Stopband Attenuation55 dB Min
Passbands5 MHz to Fo - 5 MHz and
Fo + 5 MHz to 1218 MHz
Passband Insertion Loss2 dB Max
Passband VSWR1.5:1 Typ
Impedance75 ohms
ConnectorsF-female
Size19.00" x 3.46" (2 RU) x 4.24 to 6.58" Approx.


Product Code: TULBANDSTOP
Call For Pricing

Features
 

Share your knowledge of this product. Be the first to write a review »